TTE Probe Lab - A Transthoracic Echo Simulator
Hold the probe on a chest rebuilt from CT and the echo image is made live from the plane it cuts: seventeen standard views, colour and spectral Doppler, measurements, a coach for every move and thirty patients.
Transthoracic echo is learned with a probe in the hand, and most teaching hands over pictures instead. Here the probe moves on a chest rebuilt from a contrast CT, and the echo image is made live from the plane it cuts through the heart. Slide it, rotate it, tilt it or rock it, and the picture changes the way it does at the bedside, ribs and lung included.
Nothing is a recorded loop. The image is computed from the anatomy as the probe moves, and the pressures and flows come from a beating-heart circulation model, so the Doppler belongs to the disease: the gradient across a stenosed mitral valve, the late-peaking jet of obstructive HCM, the diastolic tail of a coarctation.
Using it in a teaching session
Learn walks through the seventeen standard views: where the probe sits, where the marker points and what should be in the picture. Sweep fans the beam through a view with the structures named, then hands the probe back. Practice names a view to find and brings back the ones that were slow or wrong. Cases hands over an unknown patient to scan, measure and diagnose, with the severity varied from case to case.
The probe moves with the buttons under the image, by dragging the image itself, by dragging the probe on the chest, or from the keyboard. Switch on the coach and a line above the buttons gives the next move in a sonographer’s words, lights the button that makes it, and answers each move: good, keep going; other way; just past it. Once the plane is right it turns to the picture: lung in the way, a foreshortened apex, the depth, the gain and the Doppler angle.
On a projector, the 3D view beside the image shows the beam cutting the heart. Tap any structure on the image to name it, or fade the echo into a colour-coded anatomical section of the same plane. The saline bubble study shows when the bubbles reach the left heart: within a few beats through an ASD, only after a Valsalva release through a PFO, and four to six beats late, through the pulmonary veins, with a pulmonary AVM.
Thirty patients sit behind the patient chip: the normal heart; small, moderate and large effusions and tamponade; dilated cardiomyopathy, anterior and inferior MI, LV thrombus, and hypertrophic and obstructive cardiomyopathy; severe aortic stenosis, a bicuspid valve, severe aortic regurgitation, primary mitral regurgitation, rheumatic mitral stenosis and mitral valve prolapse; pulmonary stenosis and acute RV strain; and eleven congenital lesions, from the ASD, the PFO and the VSDs to the duct, coarctation and an intrapulmonary shunt.
What the model simplifies
The chest and heart come from one de-identified contrast CT, with the heart shifted as it lies when the patient turns onto the left side. Valve and wall motion, blood flow and every disease are modelled on top of that one anatomy, so a lesion changes the heart around it but not the patient’s build. The speckle, shadows and artefacts are computed, not filmed: close to a real scanner’s, without matching any one machine. The pressures and flows run on a lumped model of the circulation, and its numbers are the model’s calibration, not reference ranges. It teaches probe handling, echo anatomy and the look of disease; it is not for clinical use.
Sources
The views and measurements follow the ASE guidelines for a comprehensive transthoracic examination (Mitchell et al., J Am Soc Echocardiogr 2019;32:1-64) and for chamber quantification (Lang et al., J Am Soc Echocardiogr 2015;28:1-39). The organ outlines come from TotalSegmentator (Wasserthal et al., Radiology: Artificial Intelligence 2023).